v1

Parameter readout (1999, 2000)

Архивный снимок: 27.06.2026, 17:30

Изменение: Импорт из Volvo VIDA

Volvo S40 I V40 I NedCar
АРХИВ

Применимость

Модель Двигатель Год
S40 (-04) 1999, 2000
V40 (-04) 1999, 2000

Примечание: In order to allow the ECC system to function in a correct manner and to make the faulttracing easier, knobs and switches on the front of the ECC control module must be in distinct positions.

Row no. TEXT units Remarks
001 D+=V Voltage generator (GEN) D+.Ignition on = approx. 0.7-2 Vengine running = approx. 14.5 V
002 FAN KNOB=AUTO, 0, 1, 2, 3, 4 and 5 Blower fan switch, position.
003 BLOWER=% By the ECC control module choosen blower fan speed.0-100%0%=blower fan speed zero100%=blower fan speed maximumNote!When the blower fan switch is in position 0-5, the actual blower fan speed does not have to correspond to this value.When the blower fan switch is set to 5 the ECC control module connects the relay to ground terminal, which provides the blower fan motor with maximum power (battery voltage).
004 MODE KNOB=AUTO, VENT, VENT, DEFR, DEFR, DEFR, FL/DEFR, FL/DEFR, FL/DEFR, FLOOR, FLOOR, FLOOR, FLOOR, BI-LEVEL and BI-LEVEL Air distribution switch, position.Note that several positions may have the same designation.
005 MODE SHUTT.=% Damper motor position sensor, air distribution0-200%0%=DEFR15%=DEFR30%=DEFR45%=FL/DEFR60%=FL/DEFR75%=FL/DEFR90%=FLOOR100%=AUTO105%=FLOOR120%=FLOOR130%=FLOOR140%=BI-LEVEL160%=BI-LEVEL180%=VENT200%=VENT
006 TEMP KNOB=MIN, 17-27°C (11 positions, step 1°C) and MAX Interior temperature switch, position
007 TEMP SHUTT.=% Damper motor position sensor, interior temperature0-100%0%=closed damper, no heating100%=opened damper, maximum heating
008 REC SET=ON/OFF Recirculation switch, position.(disconnects the control module and switches to manual recirculation, ON).
009 AC SET=ON/OFF A/C switch, position.(disconnects A/C system, OFF).
010 AC=ON/OFF Signal, A/C request to FENIX engine control module (ECM) to start the compressor.Note!When air distribution control is in position DEFR, signal always=ON
011 SUN INTEN=W/m² Sun intensity.0-140 W/m²
012 CAB. TEMP=°C Interior temperature sensor.
013 EVAP. TEMP=°C Evaporator temperature sensor.≤+1°C (petrol), ≤ +3°C (diesel)=A/C OFF
014 WATER TEMP=°C Engine coolant temperature (ECT) sensor.
015 AMB. TEMP=°C Outside temperature sensor.
016 TIME=hours minutes Time since ignition on.
017 SPEED=km/h Vehicle speed