Применимость
| Модель | Двигатель | Год |
|---|---|---|
| S40 (-04) | — | 1999, 2000 |
| V40 (-04) | — | 1999, 2000 |
Примечание: In order to allow the ECC system to function in a correct manner and to make the faulttracing easier, knobs and switches on the front of the ECC control module must be in distinct positions.
| Row no. | TEXT units | Remarks |
|---|---|---|
| 001 | D+=V | Voltage generator (GEN) D+.Ignition on = approx. 0.7-2 Vengine running = approx. 14.5 V |
| 002 | FAN KNOB=AUTO, 0, 1, 2, 3, 4 and 5 | Blower fan switch, position. |
| 003 | BLOWER=% | By the ECC control module choosen blower fan speed.0-100%0%=blower fan speed zero100%=blower fan speed maximumNote!When the blower fan switch is in position 0-5, the actual blower fan speed does not have to correspond to this value.When the blower fan switch is set to 5 the ECC control module connects the relay to ground terminal, which provides the blower fan motor with maximum power (battery voltage). |
| 004 | MODE KNOB=AUTO, VENT, VENT, DEFR, DEFR, DEFR, FL/DEFR, FL/DEFR, FL/DEFR, FLOOR, FLOOR, FLOOR, FLOOR, BI-LEVEL and BI-LEVEL | Air distribution switch, position.Note that several positions may have the same designation. |
| 005 | MODE SHUTT.=% | Damper motor position sensor, air distribution0-200%0%=DEFR15%=DEFR30%=DEFR45%=FL/DEFR60%=FL/DEFR75%=FL/DEFR90%=FLOOR100%=AUTO105%=FLOOR120%=FLOOR130%=FLOOR140%=BI-LEVEL160%=BI-LEVEL180%=VENT200%=VENT |
| 006 | TEMP KNOB=MIN, 17-27°C (11 positions, step 1°C) and MAX | Interior temperature switch, position |
| 007 | TEMP SHUTT.=% | Damper motor position sensor, interior temperature0-100%0%=closed damper, no heating100%=opened damper, maximum heating |
| 008 | REC SET=ON/OFF | Recirculation switch, position.(disconnects the control module and switches to manual recirculation, ON). |
| 009 | AC SET=ON/OFF | A/C switch, position.(disconnects A/C system, OFF). |
| 010 | AC=ON/OFF | Signal, A/C request to FENIX engine control module (ECM) to start the compressor.Note!When air distribution control is in position DEFR, signal always=ON |
| 011 | SUN INTEN=W/m² | Sun intensity.0-140 W/m² |
| 012 | CAB. TEMP=°C | Interior temperature sensor. |
| 013 | EVAP. TEMP=°C | Evaporator temperature sensor.≤+1°C (petrol), ≤ +3°C (diesel)=A/C OFF |
| 014 | WATER TEMP=°C | Engine coolant temperature (ECT) sensor. |
| 015 | AMB. TEMP=°C | Outside temperature sensor. |
| 016 | TIME=hours minutes | Time since ignition on. |
| 017 | SPEED=km/h | Vehicle speed |