Применимость

Модель Двигатель Год
S40 (-04) B4164S 1998
S40 (-04) B4164S2 2000–2004
S40 (-04) B4184S 1998, 1999
S40 (-04) B4184S2 2000–2004
S40 (-04) B4184S3 2000–2004
S40 (-04) B4194T 1998, 1999
S40 (-04) B4194T2 2000
S40 (-04) B4204S 1998, 1999
S40 (-04) B4204S2 2000–2004
S40 (-04) B4204T 1998, 1999
S40 (-04) B4204T2 2000
S40 (-04) B4204T2 CVVT 2000
S40 (-04) B4204T3 2001–2004
S40 (-04) B4204T3 (CA) (US) 2001–2003
S40 (-04) B4204T4 2003, 2004
S40 (-04) B4204T5 2001–2003
V40 (-04) B4164S 1998
V40 (-04) B4164S2 2000–2004
V40 (-04) B4184S 1998, 1999
V40 (-04) B4184S2 2000–2004
V40 (-04) B4184S3 2000–2004
V40 (-04) B4194T 1998, 1999
V40 (-04) B4194T2 2000
V40 (-04) B4204S 1998, 1999
V40 (-04) B4204S2 2000–2004
V40 (-04) B4204T 1998, 1999
V40 (-04) B4204T2 2000
V40 (-04) B4204T2 CVVT 2000
V40 (-04) B4204T3 2001–2004
V40 (-04) B4204T3 (CA) (US) 2001–2003
V40 (-04) B4204T4 2003, 2004
V40 (-04) B4204T5 2001–2003

A3000292

All values contained below are between the terminal in column 1 and terminal #9 (ground), unless otherwise indicated in brackets.DSA control module terminals #1 - #16 correspond to #31 - #46 on the breakout box.

Примечание: It is important to connect the breakout box and check ground terminal before taking readings.

U = DC in volts (V) f = frequency in Hertz (Hz)
Ubat = battery voltage %duty = duty cycle (pulse ratio) as a percentage (%)
Ulow = Voltage approx. 0 V
Terminal Signal type Ignition on Engine idling Miscellaneous Parameter reading
#1 Power supply(from ignition switch) Ubat -
#2 Signal, wheel speed left front wheel (from ABS control module) U ≈ 0 V - Ubat depending on wheel position.Frequency (f) increases with wheel speed. Pulsed signal (0 V - Ubat) with a fixed pulse ratio (%duty ≈ 50 %).
#3 Signal, wheel speed right front wheel (from ABS control module) U ≈ 0 V - Ubat depending on wheel position.Frequency (f) increases with wheel speed. Pulsed signal (0 V - Ubat) with a fixed pulse ratio (%duty ≈ 50 %).
#4 Signal, wheel speed left rear wheel (from ABS control module) U ≈ 0 V - Ubat depending on wheel position.Frequency (f) increases with wheel speed. Pulsed signal (0 V - Ubat) with a fixed pulse ratio (%duty ≈ 50 %).
#5 Signal, throttle position (TP) sensor(from engine control module (ECM)) %duty ≈ 15 % at closed throttle position (CTP) (idling).f ≈ 50 Hz Pulsed signal (0 V - Ubat) with fixed frequency and variable pulse ratio (% duty).Pulse ratio (%duty) increases with increased throttle. 3
#6 Signal, DSA switch Switch not moved:U ≈ 0 - 3 V below UbatSwitch moved:U ≈ Ulow Signal is grounded when the switch is pressed. 8
#7 Signal, stop (brake) light switch Open: U ≈ UlowClosed: U = 0 - 1.5 V below Ubat Stop (brake) light switch closes during braking and the control module receives a signal. 11
#8 - - -
#9 Ground (for FENIX 5.1 ground via engine control unit, measured against the negative battery lead) Ulow -
#10 - - -
#11 - - -
#12 Signal, wheel speed right rear wheel (from ABS control module) U ≈ 0 V - Ubat depending on wheel position.Frequency (f) increases with wheel speed. Pulsed signal (0 V - Ubat) with a fixed pulse ratio (%duty ≈ 50 %).
#13 Signal, load (TQ)(from engine control module (ECM)) U ≈ Ulow f ≈ 33 Hz Pulsed signal (0 V - Ubat) with variable frequency and pulse ratio (% duty).Frequency increases with engine speed (RPM), pulse ratio (%duty) increases with load.
#14 Diagnostic lead U = 1 - 4 V below UbatOther values apply if the fault-tracing instrument is connected to the data link connector (DLC). -
#15 Signal, request for torque limiting(to engine control module (ECM)) f ≈ 200 Hz Pulsed signal (0 - 5 V) with fixed frequency and variable pulse ratio (% duty).
#16 Control signal, DSA warning lamp Lamp lit: U = 0 - 0.5 VLamp unlit: Ubat - 9, 10

Обсуждение и оценка

0

Пока нет комментариев. Будьте первым.